JK-BMS Wiring
The ESP32 gateway communicates with JK-BMS over UART.
Safety Warnings
- Turn off power before changing wiring.
- Do not connect battery pack voltage to the ESP32.
- Confirm the JK-BMS communication port voltage before connecting it.
- Wrong wiring can permanently damage the ESP32, JK-BMS, or battery system.
UART Wiring
- ESP32 TX connects to JK-BMS RX.
- ESP32 RX connects to JK-BMS TX.
- ESP32 GND connects to JK-BMS communication ground.
TX and RX are crossed because one device transmits while the other receives.